Jiangsu Xunfei Instrument Co., Ltd 

News

  • Why does guided wave radar level gauge need steam compensation?
    Why does the guided wave radar level gauge need steam compensation? This is mainly because the high-temperature steam environment can cause significant interference with radar waves. Under harsh conditions such as high temperature steam, the steam will scatter and absorb radar waves, which seriously affects the signal quality of the radar level gauge and ultimately leads to measurement errors. Specifically, water vapor molecules in steam absorb the energy of radar waves, which weakens the strength of the echo signal and reduces the accuracy of the measurement. At the same time, tiny water droplets suspended in the steam can also cause multipath propagation and scattering phenomena, interfering with the accurate identification of effective signals. The working principle of guided wave radar level gauge is based on the time-domain reflection principle (TDR). It relies on radar waves to propagate along steel cables or probes at the speed of light, and when the radar waves encounter the surface of the measured medium, they will reflect back to form echoes. By accurately calculating the propagation time of radar waves, the height of the liquid level can be determined. However, in high-temperature steam environments, the interference of steam can cause attenuation of radar wave energy and also lead to multipath propagation problems, which can have adverse effects on the accuracy of measurements. To solve this problem, steam compensation technology emerged. One effective method is to use guided wave radar level gauges. This type of liquid level gauge utilizes the characteristics of microwave propagation along the waveguide body by installing a waveguide rod or waveguide rope inside the container for measurement, which can significantly reduce the interference of steam on the measurement and improve the accuracy of the measurement. In addition, selecting materials that are resistant to high temperatures and corrosion to make the probe and seal of the radar level gauge, as well as optimizing the installation plan to avoid direct exposure of the radar level gauge to high temperature areas, are also effective ways to reduce the impact of steam and ensure measurement accuracy.

    2025 06/27

  • Why is the 26G radar level transmitter panel not displaying?
    26G radar level transmitter usually adopts LCD or LED display screen, with the function of switching between Chinese and English interfaces, which can display important parameters such as liquid level height, signal strength, temperature in real time. However, sometimes there may be situations where the panel does not display, which can be caused by various factors. Possible reasons for the panel not displaying 1. In terms of power supply: Disconnected power lines, blown fuses, or unstable power supply voltage can all cause the level gauge to malfunction, resulting in the panel not displaying. 2. Display module malfunction: Hardware damage or abnormal software operation of the display module may result in the inability to display measurement data properly. 3. Abnormal signal transmission: If the signal transmission line is disconnected, has poor contact, or is affected by signal interference, it can cause a no display fault. 4. Internal malfunction of the instrument: Damage to key electronic components such as microprocessors and sensors inside the level gauge can also cause the panel to not display. 5. Measurement medium issue: The dielectric constant of the measured medium is not within the measurement range of the liquid level gauge, or there are a large number of bubbles in the medium, which can also cause the panel to not display. 6. Improper calibration and setting: If the radar level gauge is not calibrated or set correctly, it will cause abnormal display of measurement values, and even result in non display. Solution method 1. Power check: First, check if the power supply of the liquid level gauge is normal, and also check if there are any problems with the power supply circuit. If a power failure is found, it can be resolved by replacing the power supply or power circuit. 2. Wiring inspection: Carefully check the signal line between the radar level gauge and the control system, and identify any wiring errors or short circuits in the signal line. For wiring faults, they can be resolved by replacing the signal wire or rewiring. 3. Panel repair or replacement: If it is confirmed that there is a malfunction in the panel of the radar level gauge, repair or replacement operations are required. You can contact professional maintenance personnel or manufacturers to assist with the handling. 4. Parameter setting check: When the level gauge panel cannot display normally, check whether the parameter settings of the radar level gauge are correct and reconfigure them according to the actual situation. In summary, to solve the problem of no display on the 26G pluse radar level measurement panel, it is necessary to start from multiple aspects such as troubleshooting and parameter configuration. Carefully inspect key parts such as power supply, signal lines, and panels, and strictly configure parameters according to the operating instructions to ensure the normal operation of the 26G radar level transmitter.

    2025 06/27

Total 2 News

Email to this supplier

-